  • Brochure WIM COMPAS ™

Technical Specifications

 

ApplicationNatural Gas, Fuel Gas, Flare Gas, Biogas, Blast Furnace Gas, Coke Oven Gas, LNG etc.
Measuring principleResidual Oxygen technology
Sample wetted partsSS316
Installation options– Safe area
– ATEX II 2G/3G Ex px [ib] IIC T3/T4 Gb (Zone 1 / 2)
– Class 1, Div. 2, Group B, C, D T3 (Zone 2 compliant)
– IECEx Ex px [ib] IIC T3/T4 Gb
– KCS Ex px [ib] IIC T3/T4 Gb
– TRCU (EAC) Ex px [ib] IIC T3/T4 Gb
– PECO (CCOE) Ex px [ib] IIC T3/T4 Gb

 

MEASURING RANGES (CONTINUOUS VERSION)
Wobbe Index0 – 100 MJ/Nm3 / 0 – 2500 BTU/scf range (50 MJ/Nm3 / 1250 BTU/scf span)1)
Accuracy< ± 0,4% of full scale for Natural Gas
Repeatability< ± 0,05% of full scale or ± 30 kJ/Nm3 (whichever is higher) 1)
Response timeT90 < 5 seconds on Natural Gas
CARI 2)0 – 25 range
Calorific Value (SG cell option)0 – 120 MJ/Nm3 / 0 – 3000 BTU/scf range (50 MJ/Nm3 / 1250 BTU/scf span) 1)
Response time CV signalT90 < 5 seconds (typically on Natural Gas)
MEASURING RANGES (INJECTION VERSION)
Calorific value0 – 120 MJ/Nm3 / 0 – 3000 BTU/scf range (50 MJ/Nm3 / 1250 BTU/scf span) 1)
Accuracy± 1,0% of full scale
Repeatability± 0,5% of full scale or ± 300 kJ/Nm3 (whichever is higher)
Update timeDefault ~30 seconds (injection interval)
Air Demand0 – 50 range
Wobbe Index (SG cell option)0 – 100 MJ/Nm3 / 0 – 2500 BTU/scf range (50 MJ/Nm3 / 1250 BTU/scf span) 1)
Update time WI SignalDefault ~30 seconds (Injection interval)

 

OUTPUTS (CONTINUOUS/INJECTION)
Local HMIFull color display with capacitive touchpad (all functions)
Analogue outputs2 off isolated 0 / 4 – 20 mA (optionally up to 4), max. 500 Ω load (active)
Digital outputs2 isolated relays (250 VAC) and 8 transistor outputs (24 VDC) standard available (optional: 6ea)
gital inputs8 digital inputs (e.g. start calibration, start validation, etc.)
Communication options–  Remote operation / Modbus TCP/IP over Ethernet or Optical fiber

–  Modbus RTU over RS485 or Optical fiber

 

UTILITIESContinuous versionInjection version
Instrument air 3)15 Nl/min0,2 Nl/min
50 Nl/min: Ex purge option ATEX / IECEx / Class  1 Div 2 / KCS / TR CU / PESO 4)50 Nl/min: Ex purge option ATEX / IECEx / Class 1 Div 2 / KCS / TR CU / PESO 4)
Sample flow± 1 Nl/min± 0.5 Nl/min
Sample pressure1,5 to 5 barg / 21,8 to 72,5 psig-0.3 to 0.5 barg / -4,4 to 7.2 psig 5)
Power supply115/230 VAC, 50/60 Hz
Power consumptionDepending on configuration (typically 1000 W, max. 2500 W)

 

INSTALLATION (CONTINUOUS/INJECTION)
MountingWall mounting
Dimensions (HxWxD)1000 x 950 x 450 mm (non-Ex version), 1200 x 900 x 450 mm (HT version)
Weight80 kg (non – Ex version), 120 kg (HT version)
Enclosure protectionEpoxy coated stainless steel (NEMA4, IP65)
Ambient temperature range5 – 40°C / 41°F – 104°F (optional down to -20°C / -4°F and/or up to 55°C / 131°F)

1) Also available in Kcal/Nm3, kWh/Nm3 etc.

2) CARI= Combustion Air Requirement Index

3) At 4 barg minimum, 10 barg maximum, dry and clean

4) Pre-purge flow: 70 Nl/min

5) Consult factory for diffferent sample pressures

6) Note: Instrument air temperature should not exceed max. ambient temperature

 


WIM COMPASTMXpress4)FlexPulsePulse HT
PStandardOOOO
CContinuous measurement version (1.5 – 5 barg / 21.3 – 72.5 psig)OO
IInjection version (-0.3 – 0.5 barg / – 4.4 – 7.2 psig)OO
115Power supply 115 VAC, 50/60 HzOOOO
230Power supply 230 VAC, 50/60 Hz – N/A for Class 1 Div 2OOOO
0No specific gravity meterOOOO
SGUHobré specific gravity meter up to 550C / 1300FOO
SGCOscillation type specific gravity meter up to 800C / 1760F (Hobre standard version)OOOO
SGC HTOscillation type specific gravity meter (High Temperature)O
0No sample pressure monitoringOOOO
SPM Sample pressure monitoringOOO
OFA 1)Oven Flow alarmOO
FPM 1)Oven flow alarm and Sample pressure monitoringOO
0Safe area versionOOOO
1ATEX II 2G Ex Zone 1 IIC T3/T4  Gb

(including Power/Signal isolation, excluding Backup purge)

OOOO
3ATEX II 3G Ex Zone 2 IIC T3/T4 Gb

(including Power/Signal isolation, excluding Backup purge)

OOO
ZCSA Class 1, Div. 2, Group B, C, D T3 versionOOOO
E1IEC Ex px [ib] IIC T3/T4 Gb

(including Power/Signal isolation, excluding Backup purge)

OOOO
KKCS Ex px [ib] IIC T3/T4 Gb (Korea)

(including Power/Signal isolation, excluding Backup purge)

OOO
PPESO/CCOE Ex px [ib] IIC T3/T4 Gb (India)

(including Power/Signal isolation, excluding Backup purge)

OOO
TTRCU/EAC Ex px [ib] IIC T3/T4 Gb (Russia)

(including Power/Signal isolation, excluding Backup purge)

OOO
22 analog outputsOOO
44 analog outputsIncludedOOO
0No serial communicationOOO
RRemote operation / Modbus TCP/IP over EthernetOOO
RORemote operation / Modbus TCP/IP over Optical fiberOOO
MModbus RTU over RS485OOO
MOModbus RTU over Optical fiberOOO
RMRemote operation / Modbus TCP/IP over Ethernet and Modbus RTU over RS485IncludedOOO
RMORemote operation / Modbus TCP/IP and Modbus RTU over Optical fiberOOO
0No extra isolated relays (standard 2 off isolated relays)OOOO
R8 off isolated relaysOOO
0No fastloop inside the analyzerOOOO
FFastloop installed inside analyzerOOOO
FA 1)Fastloop with alarm installed inside analyzerOO
0Standard ambient temperature range (5 – 40°C / 41 – 104°F)OOOO
HHeated electronics for low ambient temperature (down to -20°C / -4°F)OOOO
CCooler for high ambient temperature (up to 55°C / 131°F)OOOO
HCVersion for ambient temperature range (-20 – 55°C / -4 – 131°F)OOOO
1Analyzer suitable for wall mountingOOOO
HT High Temperature application (max. 150°C / 300°F)O
ZE 2)Zero HC Emission (max. backpressure 0.5 barg / 7.2 psig)OO
FEH2 3)Frontal Elution H2 (Hydrogen measurement)O

 

Notes:

1)        The standard Flow alarm cannot be used in the High Temperature application. Please consult Hobré if required.

2)        The Injection version is suitable for Zero HC emission operation by design.

3)        The HC (Heater/Cooler) option is mandatory in case of the Pulse HT analyzer in combination with FEH2 Hydrogen measurement.

4)        The Xpress model is suitable for Natural gas / LNG application only.