Technical specs
General |
Measuring | H2O in gaseous streams |
Service | Process optimization in powder drying food and feed, and other drying processes |
Sampling system | Vacuum, fast dual-stream selection, high-capacity filter probes |
Measuring principle | Cavity enhanced absorption spectroscopy using an infrared tunable diode laser |
| |
| |
Sample probes |
Mounting | Varinline® U&T F32/25 |
Applications | Exhaust and Inlet air streams |
Filtering | Static, 3μ, detachable and reusable |
Maximum process temperature | 120°C or 450°C |
Sample line | max 50 or 100 m, 1/4” or 1/8” diameter, no heating |
| |
| |
Measuring ranges |
Measuring range H2O | 0 – 20% vol, 0 – 160 g/kg |
Zero and span drift | Negligible |
Interference | None |
Response time analyzer | Less than 15 sec |
Precision H2O | 0.70 gram/kilo (field accuracy) |
Sample connections | Max. 2 |
| |
Outputs |
H2O | vol.% or g/kg in each sampled stream |
Analogue outputs | 2x 4 – 20 mA |
Digital outputs | Alarm Relay. Volt free contact |
Digital input | Maintenance input. volt free contact |
Interface | Display and control: PC panel with 5″7 color display |
Communication | Ethernet Modbus TCPIP; RS232 & RS485 (optional) |
Remote | Remote diagnoses by modem (optional) or by Ethernet |
| |
Installation and utilities |
Cabinet | IP65 in standard |
Access | Front door |
Weight | Approx. 40 kg including packing |
Mounting | Wall-mounted enclosure |
Dimensions cabinet | H x W x D = 800 x 600 x 250 mm |
Ambient cabinet | 20 – 30°C |
Power | 200 VA / 110 – 230 / VAC / 50 – 60 Hz / 400 Watt |